Copying and replacing drives with drives of
larger capacity
Automatic background rebuilds
Configurable stripe size and write policy per array
Intelligent drive handling:
In degraded mode: skips irreparable blocks
to continue rebuild
In normal operation: data-block verification
and repair
System Components
Single controller provides full RAID
functionalities
One (1) XDAS enhanced 4U enclosure
One (1) RAID controller module
One (1) 512MB DDR RAM DIMM module (pre-installed on
the controller module)
Three (3) hot-swappable, redundant, 405W power supply
units
Two (2) hot-swappable, redundant, dual-fan cooling
modules running in high/low speeds
Twenty-four (24) hot-swappable drive trays
Two (2) front handles
One (1) independent battery backup unit (BBU)
One (1) host connection module
Host Interface
Two(2)4G-FC host channels with embedded bypass to four (4) Fibre ports
DIP switch settings to change host port attributes
Auto-negotiate FC-AL, point-to-point, or switched
fabric
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface
Twenty-four (24) hot-swappable 3Gbps SATA-II drive
trays that accommodate 1-inch pitch, 3.5-inch SATA-II or
SATA-I disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
Management
Firmware-embedded utility via LCD keypad or RS-232C
port
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
10/100 BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to
firmware-embedded utility and UPS connectivity
Java-based SANWatch software with Snapshot protection:
Graphical user interface
Local/remote management; in-band or
out-of-band via TCP/IP
Centralized management to monitor and
administer multiple RAID units on one screen
Secure link over SSL
Configuration Client for easy access to the
configuration utility screen
SNMP 2.0 MIBs with get and set commands
SAN Management
Up to 1024 LUNs (if sufficiently large memory is used with
the proper settings)
Indicators
Onboard alarm is triggered when one of the following
fails:
RAID controller module
Cooling module
Power supply unit
Hard drive
BBU module
Host connection module
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Seven (7) per RAID controller module
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Two (2) per FC port
Module failure alert through I2C bus
Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, SMS short messages
System alerts through Java-based RAIDWatch manager
Interfaces
Four (4) FC ports that receive SFP fiber optic transceivers
Two (2) COM ports on each controller module for
RS-232C serial port (38400, n, 8, 1) and UPS support
One (1) 10/100BaseT Ethernet port on each controller
module
Power Supply Module
Two (2) redundant, hot-swappable power supplies with PFC
Cooling Module
Two (2) redundant, dual-fan cooling modules Maximum Air
Flow: High speed: 48.12 CFM
Dimensions
Chassis without handles: 445(W) x 174.4(H) x 498(D) mm
(17.5 x 6.86 x 19.6 inches)
Chassis with handles: 482(W) x 174.4 (H) x 514(D) mm
(19 x 6.86 x 20.2 inches)
Click images for larger versions.
FEATURES
- Fibre controller with two (2)
4Gbps, Hub
embedded Fibre host channels.
- Four (4) Fibre ports via independent host
connection modules for multi-path access and channel
availability
- Accommodates twenty-four (24) 3Gbps, SATA-II
hard drives, backward compatible with SATA-I drives
- Highest density 4U chassis providing up to 18TB
of storage capacity
- Support up to 2GB DDR RAM DIMM module
- Hot-Swappable Battery Backup Unit (BBU)
- Modular and passive backplane, high-availability
architecture with no single point of failure
KITDAS-704F PRICING
Part#
Description
Price
KITDAS-704F
Aberdeen XDAS 704F 18TB 4U 24-bay DAS with 4Gbps Fibre Controller to SATA II 3.0Gb/s RAID subsystem (w/ external LCD RAID control panel), Vmware Certified Solution