Copying and replacing drives
with drives of larger capacity
Automatic background rebuilds
Configurable stripe size and write
policy per array
Intelligent drive handling:
In degraded mode: skips
irreparable blocks to continue rebuild
In normal operation:
data-block verification and repair
System Components
Redundant controller configuration provides full RAID
functionalities
One (1) XDAS enhanced 3U enclosure
Two (2) RAID controller modules
Two (2) 256MB DDR RAM DIMM modules (pre-installed on
the controller modules)
Two (2) hot-swappable, redundant, 460W
power supply units
Two (2) hot-swappable, redundant, dual-fan cooling
modules running in high/low speeds
Sixteen (16) hot-swappable drive trays
Two (2) front handles
Two (2) independent battery backup units (BBUs)
One (1) enclosure configuration card
Two (2) host connection modules
Host Interface
Two (2) FC-2G host channels with
embedded bypass circuit to four (4) FC ports on two (2)
hot-swappable, independent host connection modules
DIP switch settings to change host port attributes
Auto-negotiate FC-AL, point-to-point, or switched
fabric
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface
Sixteen (16) hot-swappable 3Gbps
SATA-II drive trays that accommodate 1-inch pitch,
3.5-inch SATA-II or SATA-I disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
Management
Firmware-embedded utility via LCD keypad or RS-232C
port
Host-side SES emulation with pass-through to back-end
SES emulation
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
10/100 BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to
firmware-embedded utility and UPS connectivity
Firmware-embedded Java-based RAIDWatch® manager:
Graphical user interface
Local/remote management; in-band or
out-of-band via TCP/IP
Centralized management to monitor and
administer multiple RAID units on one screen
Secure link over SSL
Configuration Client for easy access to the
configuration utility screen
SNMP 2.0 MIBs with get and set commands
SAN Management
Up to 1024 LUNs (if sufficiently large memory is used with
the proper settings)
Indicators
Onboard alarm is triggered when one of the following
fails:
RAID controller module
Cooling module
Power supply unit
Hard drive
BBU module
Host connection module
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Six (6) per RAID controller module
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Module failure alert through I2C bus
Event notifications sent over email, fax, LAN
broadcast, SNMP traps, MSN messenger, ICQ, SMS short
messages
System alerts through Java-based RAIDWatch manager
Interfaces
Four (4) FC ports, each using a
short-wavelength adapter
Two (2) COM ports on each controller module for
RS-232C serial port (38400, n, 8, 1) and UPS support
One (1) 10/100BaseT Ethernet port on each controller
module
Power Supply Module
Two (2) redundant, hot-swappable power supplies with PFC
Cooling Module
Two (2) redundant, dual-fan cooling modules Maximum Air
Flow: High speed: 31.8 CFM
Dimensions
Chassis without handles: 445(W) x
130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
Chassis with handles: 482.6(W) x 131(H)
x 504.3(D) mm (19 x 5.2 x 19.9 inches)
Click images for larger versions.
FEATURES
- Full-featured redundant controllers with two (2)
FC-2G host channels; transfer rate up to 2Gb/s each
- Independent host connection modules that ensure
channel availability
- Accommodates sixteen (16)SATA-II hard drives,
backward compatible with SATA-I drives
- Hardware XOR engine by dedicated ASIC266
chipsets
- Support up to 2GB DDR RAM DIMM modules that are
protected by standard BBUs
- Dual-speed cooling modules to reduce noise
- SAN-ready subsystem in an enhanced modular
enclosure provides daisy chaining and clustering capabilities