ACL-8316/8312
16-bit High Resolution DAS
Card with FIFO
Features
-
16-bit high analog input resolution with
1k word on-board FIFO
-
Auto-scanning channel selection
-
100 kHz sampling rates
-
16 SE or 8 DI analog input channels
-
Bipolar input signals and programmable
gain
-
Optional two 12 bit unipolar or bipolar
-
16 digital input / output channels
-
3 independent 16-bit down counters
-
Programmable 3 A/D trigger modes and 4
interrupt sources
-
16-bit AT Bus supports 9 interrupt levels
and 16 bit DMA data transferring
-
Compact size and rugged 37-pin D-type
connector
Specifications
Analog Input (A/D)
-
ADC and resolution:
-
ADS7804 or equivalent (12 bits for
ACL-8312)
-
ADS7805 or equivalent (16 bits for
ACL-8316)
-
Number of channels: 16 single-ended or
8 differential input
-
Conversion time: 8 µ sec
-
Maximum sampling rate: 100 kHz max. multiplexing
-
Input signal range:
Bipolar: +10V, +5V,
+2.5V, +1.25V
-
On board memory: 1k word FIFO
-
Data format: Two's complement
-
A/D trigger sources:
3 trigger sources: Includes software
trigger, pacer trigger and external trigger
-
Data transfer mode:
Software
polling, EOC Interrupt transfer, FIFO polling, FIFO Half-full interrupt, and
DMA transfer
Analog Output (D/A)
-
DAC: B.B. DAC2813 or equivalent
-
DA resolution: 12 bits
-
Number of channels: 2 channels
-
Voltage output range: (jumper selectable)
Bipolar: +10V or Unipolar:
0~10V
-
Settling time: 4.5 Łg sec typical
-
Output driving capacity: +5 mA
-
Data format: Two's complement or binary
code
Digital Input & Output (DIO)
-
Number of channels: 16 DI channels and
16 DO channels
-
I/O characteristics: TTL compatible
Programmable Counter
-
Device: 82C54
-
A/D pacer timer: 32 bits with 2MHz time
base
-
Counter: One 16 bits down counter
Interrupt source:
-
4 interrupt sources including timer pacer,
EOC, external source, and FIFO half-full interrupt
General Specifications
-
IRQ levels: 3, 5, 6, 7, 9, 10, 11, 12, 15
-
DMA level: 5, 6, 7 (16 bit DMA)
-
Operation temperature: 0° ~ 55°C
-
Storage temperature: -20° ~ 80°C
-
Humidity: 5~95%, non-condensing
-
Power consumption
-
+5V @ 400 mA typical
-
+12V@ 260 mA typical
-
Dimensions: 163 mm x 123 mm
Termination Boards
Ordering Information
-
ACL-8316
16 bit DAS Card with FIFO
-
ACL-8312
12 bit DAS Card with FIFO
-
ACL-8316/L, ACL-8312/L
ACL-8316[8312] lite version: without DA
-
ACL-8316/25, ACL-8312/25
ACL-8316 [8312] + ACLD-8125
(Includes 1m cable ACL-10137-1)
View Manual View Specifications from Catalog
All PDF formated files in this website
are best viewed using Adobe Acrobat Reader Version 4 and above. You can download
a free copy from Adobe's
Web Site.
|
|
|